Leak and pressure tests in magnets production chain презентация

Слайд 2

Applied helium leak test methods

A) Enclosure test (integral leak detection);
B) Spray technique

(local leak detection);
С) Enclosure test (integral leak detection);
D) Sniffer technique (local leak detection)
E) Bubble test
Leak detectors:
ASM310
ASM380
HLT575
ASM340

Maximum sensitive:
5×10-13 Пам3/с (5×10-12 mbar•l/с)

Applied helium leak test methods A) Enclosure test (integral leak detection); B) Spray

Слайд 3

Enclosure test

Isolators
Tubes
Parts of magnets (sometimes)

Sensitive: 5×10-13 Пам3/с
Summarize leak

Enclosure test Isolators Tubes Parts of magnets (sometimes) Sensitive: 5×10-13 Пам3/с Summarize leak

Слайд 4

Sniffer test

Connections
Magnets after cryogenic test
Magnets with problems

Sensitive: 5×10-9 Пам3/с
Place of leak;
Leak can be

calculated

Sniffer test Connections Magnets after cryogenic test Magnets with problems Sensitive: 5×10-9 Пам3/с

Слайд 5

Spray technique

Parts of magnets before cryotest
Magnets before cryotest
Another items for vacuum

Sensitive: 5×10-13

Пам3/с
Place of leak;
Leak can be calculated;

Spray technique Parts of magnets before cryotest Magnets before cryotest Another items for

Слайд 6

Enclosure test (main test for magnets)

Magnets
Tubes
Another items with helium inside

Sensitive: 5×10-13 Пам3/с
Summarize

leak;

Enclosure test (main test for magnets) Magnets Tubes Another items with helium inside

Слайд 7

Test bench for enclosure test

Magnets
Tubes
Pressure test is done last leak test

Test bench for enclosure test Magnets Tubes Pressure test is done last leak test

Слайд 8

Enclosure test under the helium temperature

Enclosure test under the helium temperature

Слайд 9

Enclosure test under the helium temperature

Magnets

Sensitive: 5×10-13 Пам3/с
Temperture;

Enclosure test under the helium temperature Magnets Sensitive: 5×10-13 Пам3/с Temperture;

Имя файла: Leak-and-pressure-tests-in-magnets-production-chain.pptx
Количество просмотров: 204
Количество скачиваний: 0