NIR Spectroscopy Principle Beer–Lambert law Logarithmic dependence between the transmission

NIR Spectroscopy Principle

Beer–Lambert law

Logarithmic dependence between the transmission T, of

light through a substance and the product of the absorption A coefficient of the substance, α, and the distance the light travels through the material (i.e. the path length), ℓ.
Слайд 3

NIR Analyzers Advantage Low Cost of Ownership Optimized production processes

NIR Analyzers Advantage

Low Cost of Ownership
Optimized production processes by real time

monitoring
Improved process knowledge
Expensive and time consuming
laboratory analyses are no longer
necessary
Improved quality assurance
Minimal maintenance required
Easy to calibrate - automatic calibration model updating
Powerful communication system
Слайд 4

Beacon 3000 NIR Analyzer Advantage Connection to up to 8

Beacon 3000 NIR Analyzer Advantage
Connection to up to 8 process stream

sensors
No longer location-specific can be situated up to 2 miles (3,2km) away from main analyzer
Use of standard telecommunication fiber optics
Contains no moving parts
No electricity required
Слайд 5

Block Diagram

Block Diagram

Слайд 6

Field Unit Operation Conditions Haze free Max. Pressure - 550

Field Unit Operation Conditions

Haze free
Max. Pressure - 550 psi (40 bar)
Flow rate -

1 l/min to 3 l/min
Temperature - Above Cloud point to +160°C (300°F)

Field Unit Sample Cell Probe

Слайд 7

No Effect of Fiber Length Wavelength, nm

No Effect of Fiber Length

Wavelength, nm

Слайд 8

From Spectral Information to Electronic Data Field Unit Detector Module

From Spectral Information to Electronic Data

Field Unit

Detector Module

Measured Spectra

Processor

Measured Spectra

Properties


Calculation

Reports

Light
Source

Слайд 9

Online Sample Collection and Model Building Analyzer Control Room Plant

Online Sample Collection and Model Building

Analyzer

Control
Room

Plant Lab

Service
Center

Save
Spectrum

Save
Spectrum

Model

Field Process

Слайд 10

Principles of Chemo-metrics Calibration Model Reference Measurements + Calibration Phase

Principles of Chemo-metrics

Calibration Model

Reference Measurements

+

Calibration Phase

Measurement Phase

Unknown Spectra

+

Calibration Model

Real Time

Results

Reference Spectra

Слайд 11

Typical Gasoline Spectra Wavelength, nm

Typical Gasoline Spectra

Wavelength, nm

Слайд 12

X and Y Data Spectra Property X data Y data

X and Y Data

Spectra

Property

X data

Y data

Single Spectrum (x1 , x2 ...

xn )

Wavelength, nm

Слайд 13

MON of Gasoline - Universal Model NIR Reference

MON of Gasoline - Universal Model

NIR

Reference

Слайд 14

Note on Lab Results

Note on Lab Results

Слайд 15

Statistic Nomenclature Root Mean Square Error of Prediction Standard Error

Statistic Nomenclature

Root Mean Square Error of Prediction

Standard Error of Prediction

Average Difference

between and in Prediction Set

- laboratory reference

- calculated value

Слайд 16

Modcon Solution Free-tune Software This software program is composed of

Modcon Solution

Free-tune Software
This software program is composed of two sequential blocks:
PLS

regression is used to build a localized sensitive model (LSM) based on just a small number of samples. One of the characteristics of this model is its sensitivity to short term (hours) process variations. Since it is localized, the model can be quickly built and validated. This procedure takes up to one week and can be performed prior to startup.
A proprietary software program processes the model, together with the specified plant data, to accurately quantify the properties. This part deals with predicting the long-term product variability.
Слайд 17

Model Updating Model updating during the crude switching

Model Updating

Model updating during the crude switching

Слайд 18

Fusion Solutions Sample System Discrete Analyzer Modbus Distributed Control System

Fusion Solutions

Sample
System

Discrete Analyzer

Modbus

Distributed
Control System

NIR Analyzer
with Freetune*
software

Stream 1

Stream 2

Stream 3

Fiber optic cable

Response

time: 5-10 min
Accuracy: according to ASTM
Availability: above 98% (full-redundant system)

NIR

NIR

NIR

Слайд 19

Слайд 20

Слайд 21

Слайд 22

Слайд 23

Слайд 24

Слайд 25

Слайд 26

Слайд 27

Слайд 28

Слайд 29

Слайд 30

Слайд 31

Слайд 32

Слайд 33

Слайд 34

Слайд 35

Слайд 36

Слайд 37

Слайд 38

Слайд 39

Слайд 40

Слайд 41

Слайд 42

Имя файла: NIR-Systems.pptx
Количество просмотров: 117
Количество скачиваний: 0